military cots power supply
  • Three 36W Models:
    • 12V @ 3A
    • 24V @ 1.5A
    • 28V @ 1.3A
  • Output voltage options of  18V & +48V are available (contact factory for more information)
  • Designed to meet Meet FCC Part 15 Class B, CISPR22.2 Class A
  • Rugged metal enclosure with potting offers improved shock and vibration performance and resistance to environmental factors
  • Universal input 100~240V +/- 10%
  • Convection cooled
  • Compact size

DB9 Connector (DB15 shown in photos)

Waterproof/Dustproof to IP67

Input Characteristics
Voltage and Frequency 90 ~ 264Vac, 47 ~ 63Hz
AC Current 1A Max. at any Input voltage range at Max. load condition
Inrush Current (Typ.)  less than 40A at 120V ~ 240V input (Optional low inrush model: less than 15A at 110V input and less than 30A at 220V input
Leakage Current <0.75mA/240Vac @60Hz
Output Characteristics Part #: RTPS 36-12-01 Part #: RTPS 36-24-01 Part #:RTPS 36-28-01
Output Voltage 12V 24V 28V
Current (A) Minimum 0A 0A 0A
Current (A) Maximum  3A  1.5A  1.3A
Voltage Initial Setting +/- 1% +/- 1% +/- 1%
Combined Load/line Regulation Output maximum full rated o/p, CURRENT regulation +/-5%
Ripple and Noise The ripple and noise is as follows when measured with a maximum bandwidth of 20MHz and 4.7uF/50V capacitor connected at output wire shall be less that 1% P-P
Efficiency 81% minimum at 120~240Vac at maximum load
Hold Up Time 8mS minimum

Protection Specifications
Over Current Output limited less than 120% max rated output current
Short Circuit Output shall shut down and automatic restart
Over Voltage Power supply shall not exceed 115% ~130% of rated output voltage
Over Temperature Power supply shall reduce the output voltage and current at the out of spec high temperature condition and maintain the hot spot temperature below components rating
Environment Specifications
Operating Temperature Nominal -40 to +60°C ambient at full load Linearly de-rate output power to 70% up to 80°C
Operating Humidity 5% to 95%, non-condensing
Cooling Requirement Natural air convection cooling
Storage Temp., Humidity -40 ~ +85°C 10 ~95% R.H
Altitude 15,000 ft minimum operation and -500ft to 40,000 ft storage
Vibration Frequency 5 to 50 Hz, acceleration ±7.35 M/(S*S), direction X,Y and Z Axis

Safety And EMC
Safety Standards Compliant to UL1310 with class 2 output and UL60950 requirement
EMI Conduction & Radiation Meets FCC Part 15 Class B, CISPR22.2 Class A
Reliability Mean Time Between Failure (MTBF) >100,000 hours, MIL-HDBK217E at 40 degrees C ambient.
EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
Isolation
  • 1500VAC minimum from AC input to DC output
  • 1500VAC minimum from AC input to Chassis Ground
  • 500VAC minimum from DC output to Chassis Ground
Burn-In 48 hours at 100% rated load prior to final testing
MTBF 200K hrs minimum at 25C, convection cooled, per part calculation method
Warranty 3 Years

Mechanical Specifications
Physical Construction Rugged metal enclosure with potting offers improved shock and vibration performance and resistance to environmental factors
Dimensions 5.5(L) X 2.75(W) X 1.5(H) INCH
AC Input Cable 36~48” Black 18AWG wires, White ( Neutral), Black ( Line), Green ( Chassis)
DC Output Cable 36” +/-2″, with D-Sub 9 pin connector
36W COTS Power Supply Mechanical Drwg
Output Pin Specifications
 Pin 1  Chassis/Ground Pin 6 +12Vdc Return
 Pin 2  N/C Pin 7 +12Vdc Return
Pin 3 N/C Pin 8 +12Vdc Return
Pin 4 +12Vdc Pin 9 +12Vdc Return
Pin 5 +12Vdc

acrobat-10-icon
For More Information…